Chapter 6 Introduction to the supporting products
window shown in 10.4.4 is set to OFF, it is enabled while external input points are switched on
(JP4-17 and common port JP4-12 switched on); (2) or if ―Time controlled service floor scheme 1‖
in the window shown in 10.4.4 is set to ON, it is enabled by internal timing.
7) Scheme 2 (NS-2 Car): Set up the landings of each single elevator which could receive the
instruction service in scheme 2.
8) Scheme 2 Up Call (NS-2 Up): Set up the landings of each single elevator which could
receive the up call service in scheme 2.
9) Scheme 2 Down Call (NS-2 Down): Set up the landings of each single elevator which
could receive the down call service in scheme 2. A common starting condition for setups in items
7~9 abovementioned in this section content: (1) If ―Time controlled service floor scheme 2‖ in the
window shown in 10.4.4 is set to OFF, it is enabled while external input points are switched on
(JP4-16 and common port JP4-12 switched on); (2) or if ―Time controlled service floor scheme 2‖
in the window shown in 10.4.4 is set to ON, it is enabled by internal timing.
10) Setup Method: Firstly choose the contents in any one of items 2~9 above, then set in
item 1. Then, mark or remove √ in the boxes before numbers of 1~48 in natural ordering floor of
elevators from bottom to top in group control. If √ is marked, it represents that this floor can
provide service in this item; contrarily, this floor cann‘t provide service in this item.
11) Read: Read the parameters set and saved last time in this window from the group control
board.
12) Set: Save the currently set parameters in the group control board in this window. If any
parameter is modified, it is necessary to click this button to transfer the set parameters to the group
control board for storage, and then parameter setup finishes.