Shanghai STEP Electric Corporation
of 7-segment code. When need to modify, press enter key the figure in the lowest order start to
flash. Use left or right key to select the figure required for modification. The selected figure starts
to flash. Then use the up or down button to modify the figure. Press the enter button to confirm the
modification.
7 Hoist way parameter
The parameter shows the data of floor hoist way, the length of leveling plate, distance of leveling
switch, deceleration switch position. The detailed operation is as follow: Use up or down button to
select the needed parameter. For example, P02, the screen displays the above P.02. Then the there
will display the 03.000, the value of P02 parameter, on screen after waiting for one second. Then
Both P.02 and 03.000 will display alternatively. Each displays for one second. The parameter
shows that there are 3 meter high between the first floor and second floor. The definition of each
parameter is as follow:
Table 5.3 hoist way parameter definition
Leveling switch center distance
1 floor up deceleration switch distance
2 floor up deceleration switch distance
3 floor up deceleration switch distance
4 floor up deceleration switch distance
1 floor down deceleration switch distance
2 floor down deceleration switch distance
3 floor down deceleration switch distance
4 floor down deceleration switch distance
8 car top panel input condition