Instruction Manual for AS380 Series Elevator Integrated Drive Controller
up level-1 forced deceleration switch on-off
up level-2 forced deceleration switch on-off
up level-3 forced deceleration switch on-off
up level-4 forced deceleration switch on-off
up limit switch status- light off, do not move up
up leveling switch on-off
down leveling switch on-off
door lock relay ( X17/parameter setting-if no normal light)
Quick car running
startup condition. All
these 11 light on
means the peripheral
signal ok, the startup
condition for quick car
running is met
main contactor contact input signal ( contactor no adhesion and
light on)
band brake contactor contact input signal( contact no adhesion and
light on)
up limit switch ( compound) status signal
down limit switch ( compound ) status signal
door close limit switch signal ( front and rear door)
light on when no internal startup fault exist
front valid signal registration existed or not
auto hi-speed status signal
main contactor drive signal
The internal status of
quick car running. All
six light on one by one
when the quick car run
normally.
up direction/down direction signal
running signal feed from drive part
band brake contactor drive signal
front door open limit on-off
Door open/close
signal. Light on mean
external input point is
connected.
front door close limit on-off
rear door open limit on-off
rear door close limit on-off
front door safety edge switch on-off
rear door safety edge switch on-off
front door light curtain switch on-off
rear door light curtain switch on-off
present floor door open signal
light on when in attendant status or independent status
light on when in firemen operation status
main contactor contact input on-off
Contact inspection
signal, light on mean
external signal
connected.
band brake contactor contact input on-off
No 1 band brake inspection switch contact input on-off
No 2 band brake inspection switch contact input on-off
safety circuit high-voltage point input on-off
safety circuit relay contact input on-off
door lock circuit high-voltage point input on-off
door lock relay contact point input on-off
main contactor drive output
band brake contactor drive output
Main input signal
logic status
down level-1 forced deceleration switch status