C-6 SPARCclassic/SPARCclassic X/SPARCstation LX Service Manual November 1993
For example:
The watch-net-all command monitors Ethernet packets on any Ethernet interface
installed in the system. For example, if you have an SBus Ethernet card installed in
one of the system SBus slots, watch-net-all will start by monitoring Ethernet
transmissions detected by that card.
When you interrupt the test on that interface by pressing any key, watch-net-all then
goes on to test the next Ethernet interface it finds in the system.
For example:
ok watch-tpe
Internal loopback test -- succeeded.
External loopback test -- succeeded.
Looking for Ethernet packets.
‘.’ is a good packet. ‘X’ is a bad packet.
Type any key to stop.
...............................................................
ok watch-net-all
/iommu@f,e0000000/sbus@f,e0001000/lebuffer@1,40000/le@1,60000
Internal loopback test -- succeeded.
External loopback test -- succeeded.
Looking for Ethernet packets.
‘.’ is a good packet. ‘X’ is a bad packet.
Type any key to stop.
................................................................
...................(keyboard key pressed here)
/iommu@f,e0000000/sbus@f,e0001000/ledma@f,400010/le@f,c00000
Internal loopback test -- succeeded.
External loopback test -- succeeded.
Looking for Ethernet packets.
‘.’ is a good packet. ‘X’ is a bad packet.
Type any key to stop.
................................................................
..............................................................