TABLE A–2 Environmental Requirements
Operating Environment
Temperature between 0 to 40 degrees C (32 and 104 degrees F)
Humidity 5 to 95% relative humidity
Altitude 70.1 kPa (3 km or 9,843 ft equivalent))
Vibration 0.25G peak all axes, 1 sweep at 1 octave/min., 5-500-5 Hz 10 minute
dwell at a maximum of 4 resonant frequencies
Shock 5G half sine 11 msec, 10 impacts each on all 6 surfaces, 0.343 m/sec
velocity change
Acoustic noise 5.1 bels (<28 degrees C or 82.4 degrees F environment)
Idle Acoustic
Noise
5.0 bels (<28 degrees C or 82.4 degrees F environment (per declared noise
emissions in accordance with ISO 9296)
Non-Operating Environment:
Temperature between –40 to 75 degrees C or –40 to 167 degrees F)
Humidity 95% relative humidity
Altitude 19.3 kPa (12 km or 39,370 ft)
Vibration 1.0G peak all axes, 12 mm peak-peak, 1 sweep at 1 octave/min. 5-500-5
Hz 10m minute dwell at a maximum of 4 resonant frequencies
Shock 3.5 m/sec velocity change, 3 msec max. pulse duration, 3 impacts each on
all 6 surfaces
Handling drops 1 rotational flat drop each edge, 1 rotational edge drop each edge 80 mm
drop height, 40 mm block height
Mechanical
Connections
100 inserts per connector, 100 opening/closing of top cover, 100 on/off
operations of each switch
176 SPARCstation 10 Service Manual ♦ Revision A, July 1993