Exhaust System: 1K-3
Installation
Install the exhaust pipe/muffler in the reverse order of
removal. Pay attention to the following points:
CAUTION
!
Replace the exhaust pipe gasket (1) and
exhaust pipe connector (2) with the new
ones.
Install the exhaust pipe gasket (1) and exhaust pipe
connector (2).
Tighten the exhaust pipe bolts (3) to the specified
torque.
Tightening torque
Exhaust pipe bolt (a): 23 N·m (2.3 kgf-m, 16.5 lb-
ft)
Tighten the HO2 sensor (4) to the specified torque.
Tightening torque
HO2 sensor (b): 48 N·m (4.8 kgf-m, 34.5 lb-ft)
CAUTION
!
Be careful not to expose it to excessive
shock.
Do not use an impact wrench while
installing the HO2 sensor.
Be careful not to twist or damage the
sensor lead wires.
Do not apply oil or other materials to the
sensor air hole.
Apply thread lock to the exhaust pipe joint bolt and
muffler mounting bolts.
: Thread lock cement 99000–32050
(THREAD LOCK CEMENT 1342 or equivalent)
Tighten the exhaust pipe connecting bolt (5) and
muffler mounting bolts (6) to the specified torque.
Tightening torque
Exhaust pipe connecting bolt (c): 23 N·m (2.3 kgf-
m, 16.5 lb-ft)
Muffler mounting bolt (d): 23 N·m (2.3 kgf-m, 16.5
lb-ft)
1
I705H11B0007-03
2
I705H11B0008-02
(a)
3
I705H11B0009-02
(b)
4
I705H11B0010-02
(c)
5
(d)
6
I705H11B0011-02