Charging System: 1J-11
Charging
For initial charging, use the charger specially designed
for MF battery.
CAUTION
!
For charging the battery, make sure to use
the charger specially designed for MF
battery. Otherwise, the battery may be
overcharged resulting in shortened service
life.
Do not remove the cap during charging.
Position the battery with the cap facing
upward during charging.
Battery Recharging
CAUTION
!
Do not remove the caps on the battery top
while recharging.
NOTE
When the motorcycle is not used for a long
period, check the battery every 1 month to
prevent the battery discharge.
1) Remove the battery from the motorcycle. Refer to
“Battery Removal and Installation (Page 1J-12)”.
2) Measure the battery voltage using the multi-circuit
tester.
If the voltage reading is less than the 12 V (DC),
recharge the battery with a battery charger.
Recharging time
0.9 A for 5 to 10 hours or 4 A for 1 hour.
CAUTION
!
Be careful not to permit the charging current
to exceed 4 A at any time.
3) After recharging, wait at least 30 minutes and then
measure the battery voltage using the multi-circuit
tester.
If the battery voltage is less than 12.5 V, recharge
the battery again.
If the battery voltage is still less than 12.5 V after
recharging, replace the battery with a new one.
4) Install the battery to the motorcycle. Refer to “Battery
Removal and Installation (Page 1J-12)”.
Correct
Incorrect
I649G11A0047-02
“A”: Charging period “B”: Stop charging
“A”
“B”
I649G11A0045-02
I310G11A0030-01