The file structure of a generated CSV is shown in the table below.
Section
File contents
File header
// **********************************************************************
// CSV file version, 1.18
// Created, 11/01/2015, 20:43:24
// Unit, 200, SN, 26858
// Firmware, 1.20.7, 14/11/2014
// Corresponding logger file name, L1.SVL
// Device function, SLM
// Integration time, 00:00:01
// Leq integration, linear
// Outdoor filter, environmental
// Profile 1, A, FAST
// Profile 2, C, FAST
// Profile 3, Z, FAST
// Statistical levels, 1, 10, 20, 30, 40, 50, 60, 70, 80, 90
// CSV save mask, 0FFF, 0FFF, 0FFF, 7
// SLM results, profile 1, TIME, PEAK, MAX, MIN, SPL, LEQ, SEL, Lden, Ltm3, Ltm5, Lnn, OVL
// SLM results, profile 2, TIME, PEAK, MAX, MIN, SPL, LEQ, SEL, Lden, Ltm3, Ltm5, Lnn, OVL
// SLM results, profile 3, TIME, PEAK, MAX, MIN, SPL, LEQ, SEL, Lden, Ltm3, Ltm5, Lnn, OVL
// **********************************************************************
Record number
// Record No, 1
Time sgnature
DT, 11/01/2015, 20:43:25
Measurement
data
P1, 1, 56.0, 42.7, 39.6, 42.7, 41.5, 41.5, 46.5, 42.7, 42.7, 42.9, 42.8, 42.6, 42.4, 42.2, 42.0, 41.0, 40.5, 40.0, 38.5, 0
P2, 1, 62.3, 53.9, 47.8, 53.9, 49.8, 49.8, 54.8, 53.9, 53.9, 51.9, 51.5, 51.0, 50.5, 50.0, 49.5, 49.0, 48.5, 48.0, 47.5, 0
P3, 1, 66.7, 59.0, 47.3, 59.0, 57.5, 57.5, 62.5, 59.0, 59.0, 59.9, 59.0, 58.5, 58.0, 57.7, 57.5, 57.2, 57.0, 56.6, 56.3, 0
Record number
// Record No, 2
Time sgnature
DT, 11/01/2015, 20:43:26
Measurement
data
P1, 1, 56.9, 45.4, 41.4, 45.4, 42.8, 42.8, 47.8, 45.4, 45.4, 46.9, 46.0, 43.0, 42.7, 42.5, 42.2, 42.0, 41.6, 41.3, 41.0, 0
P2, 1, 63.3, 52.6, 47.9, 52.6, 50.4, 50.4, 55.4, 52.6, 52.6, 53.9, 53.6, 53.3, 53.0, 48.7, 48.5, 48.2, 48.0, 47.6, 47.3, 0
P3, 1, 67.8, 59.2, 54.0, 59.2, 56.6, 56.6, 61.6, 59.2, 59.2, 59.9, 59.5, 59.0, 57.0, 55.6, 55.3, 55.0, 54.6, 54.3, 54.0, 0
Record number
// Record No, 3
Time sgnature
DT, 11/01/2015, 20:43:27
Measurement
data
P1, 1, 57.6, 41.7, 37.6, 41.7, 39.1, 39.1, 44.1, 41.7, 41.7, 42.9, 42.0, 41.0, 39.0, 38.7, 38.5, 38.2, 38.0, 37.5, 37.0, 0
P2, 1, 62.9, 53.2, 49.6, 53.2, 50.9, 50.9, 55.9, 53.2, 53.2, 54.9, 54.0, 50.8, 50.7, 50.5, 50.4, 50.2, 50.1, 50.0, 49.5, 0
P3, 1, 68.9, 64.0, 56.9, 64.0, 61.9, 61.9, 66.9, 64.0, 64.0, 63.9, 63.6, 63.3, 63.0, 62.0, 61.6, 61.3, 61.0, 60.5, 60.0, 0
Note: CSV files take up a lot of storage space and transmission bandwidth during data
downloading.
Result selector

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Svantek SV 200A and is the answer not in the manual?

Svantek SV 200A Specifications

General IconGeneral
BrandSvantek
ModelSV 200A
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals