Removal and Installation Procedures
SPG600 & SPG300 Sync Pulse Generators Service Manual 6-17
Procedure for SPG600 Internal Modules
Perform the Access Procedure (on page 6-12) before doing any procedure in this
group. The procedures are:
A30 Analog board (Option 02 only)
A40 SDI board (Option 03 only)
A10 Main board
Power supply module
A30 Analog Board (Option
02 Only)
1. Locate module to be removed: Locate the A30 Analog board in the locator
diagram SPG600 Internal modules, Figure 6-3, on page 6-9.
2. Orient the instrument: Set the SPG600 so its bottom is down on the work
surface and its right side is facing you.
3. Remove the A30 Analog board: See Figure 6-9.
a. Unplug the cable from the A10 Main board at J1.
b. Use a screwdriver with #1 Phillips tip to remove the two screws securing
the A30 Analog board to the rear of the chassis.
c. Use a screwdriver with #2 Phillips tip to remove the two screws securing
the A30 Analog board to the bottom of the chassis.
d. Lift the board up and away from the chassis to complete the removal.
4. Reinstallation: Perform step 3 in reverse order to reinstall the A30 Analog
board.