Operating Basics
36 TDS5000B Series Quick Start User Manual
3. Turn AutoBright on or off. On au-
tomatically sets the maximum in-
tensity to the v alue of the most
frequent event. Off creates a dis-
play like an analog oscilloscope.
The displayed brightness depends
on the trigger rate.
2
3
4. To show more detail than other
color palettes when using FastAcq
mode, select Colors, and then se-
lect Temp or Spectral color pal-
ettes from the Fast/Acq WfmDB
Palette. Temp displays frequently
occurring events in red shades
and infrequent events are dis-
played in blue and green shades.
Spectral displays events exactly
the opposite of Temp.
4
Quick Tips
H Use FastAcq mode when you want to acquire data at exceptionally fast rates. FastAcq mode combines the
data from all trigger events into a single pixel map.
H FastAcq mode only works with Sample acquisition mode. Turning on FastAcq while in any acquisition mode
other than Sam ple, causes the instrument to switch to Sample acquisition mode.
H Increase the intensity to make less frequently acquired points brighter in the display.

Table of Contents

Other manuals for Tektronix TDS5000B Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix TDS5000B Series and is the answer not in the manual?

Tektronix TDS5000B Series Specifications

General IconGeneral
BrandTektronix
ModelTDS5000B Series
CategoryTest Equipment
LanguageEnglish

Related product manuals