RiverPro and RioPro ADCP Guide October 2017
EAR-Controlled Technology Subject to Restrictions Contained on the Cover Page.
Page 91
CF Set Control Flags
Purpose Sets various RiverPro/RioPro data flow-control parameters.
Format CFnnnnn
Range Firmware switches (see description)
Default CF11111
Recommended Setting. The default setting for this command is recommended for most applications.
Description The CF-command defines whether the RiverPro/RioPro: generates data ensembles auto-
matically or manually; generates pings immediately or manually; sends serial output data
in binary or Hex-ASCII format; sends or does not send output data to the serial interface.
Table 12: Set Control Flags
Command Description
CF1xxxx Automatic Ensemble Cycling Automatically starts the next data collection cycle after the current cycle is completed. Only a
<BREAK> can stop this cycling.
CF0xxxx Manual Ensemble Cycling Enters the STANDBY mode after transmission of the data ensemble, displays the “>” prompt and
waits for a new command.
CFx1xxx Automatic Ping Cycling Pings immediately when ready.
CFx0xxx Manual Ping Cycling Sends a < character to signal ready to ping, and then waits to receive an <Enter> before pinging. The
<Enter> sent to the RiverPro/RioPro is not echoed. This feature manually controls ping timing within the ensemble. Note the
prompt output by the RiverPro/RioPro when ready to ping is a less-than symbol (<), to distinguish it from the normal com-
mand prompt.
CFxx2xx Hex-ASCII Data Output, Carriage Return-Linefeed delimited -- Sends the ensemble in readable hexadecimal-ASCII format with
a Carriage Return-Linefeed at the end of each ensemble, if serial output is enabled (see below).
CFxx1xx Binary Data Output Sends the ensemble in binary format, if serial output is enabled (see below).
CFxx0xx Hex-ASCII Data Output Sends the ensemble in readable hexadecimal-ASCII format, if serial output is enabled (see below).
CFxxx1x Enable Serial Output Sends the data ensemble out the RS-232/422 serial interface.
CFxxx0x Disable Serial Output No ensemble data are sent out the RS-232/422 interface.
CFxxxx1 Reserved
CFxxxx0 Reserved