Performance and Testing Commands
The RiverPro/RioPro uses the following commands for calibration and testing.
Available Performance and Testing Commands
This section lists the available Performance and Testing commands.
>p?
Available Commands:
PA ---------------------- Run Go/No-Go Tests
PC ---------------------- Built In Tests [0=help]
PD 0 ----------------- Set Output Format (0=ensemble; 1=vbeam)
PS ---------------------- System Info [0=config,3=xform]
PT ---------------------- Built-in-Test Commands; PT0=Help
PF ---------------------- Results from most recent PA tests
P? ---------------------- Display P-Command Menu
>
Performance and Testing Command Descriptions
PA Run Go/No-Go Tests
Purpose Sends/displays results of a series of RiverPro/RioPro system diagnostic tests.
Format PA
Recommended Setting. Use as needed.
Description These diagnostic tests check the major RiverPro/RioPro modules and signal paths. These
tests check the following boards/paths.
Recorder - verifies recorder operation (this test takes several minutes to com-
plete).
DSP - RAM, ROM, and DSP-to-CPU Communications.
Sensors - verifies sensor operation.
Example see below
>pa
RAM test................PASS
ROM test................PASS
RTC test................PASS
UART test...............PASS
Compass test............PASS
Temperature test........PASS
Recorder test...........PASS
GO
>