RiverPro and RioPro ADCP Guide October 2017
EAR-Controlled Technology Subject to Restrictions Contained on the Cover Page.
Page 89
Control System Commands
The RiverPro/RioPro uses the following commands to control certain system parameters.
Available Control System Commands
This section lists the available Control System commands.
>C?
Available Commands:
CA 0 ---------------- Communication Timeout (0=Off,10-65536 sec)
CB 811 ------------------ Serial Port Control {baud;parity;stop}
CF 11111 ---------------- Set Ctrl Flags {e;p;b;s;*}
CK ---------------------- Save Command Parameters to Flash
CR ---------------------- Restore Cmd defaults [0=user,1=factory]
CS ---------------------- Start Pinging
CSTATE ------------------ Pinging State Query
CSTOP ------------------- Stop Pinging
CT 0 -------------------- Turnkey (0 = OFF, 1 = ON)
CW ---------------------- Output the Last Stored Ensemble
CZ ---------------------- Put the system to sleep.
C? ---------------------- Display C-Command Menu
>
Control System Command Descriptions
CA Communication Timeout
Purpose Sets the timeout period for the activity timer.
Format CAnnnnn
Range nnnnn = 0 (off), 10 to 65536 seconds
Default CA0
Recommended Setting. The default setting for this command is recommended for most applications.
Description The CA command sets the activity timeout period, in seconds. The activity timer is reset
when a valid command is received. If no valid command is received within the timeout
period, the RiverPro/RioPro will go to sleep or deploy itself, depending on the setting of
the CT (Turnkey) command. If Turnkey mode is enabled (CT1) then the RiverPro/RioPro
will self-deploy after the activity timeout period has elapsed.

Table of Contents

Related product manuals