CONFIGURATION FILES
CHAPTER 5
62
ECOTEL 3G 16.1. Revised: 1 March 2011.
ANA[<country-
code>,<charge-
freq>,<cid-T5>,<cid-
max-short>,<cid-min-
long>,<cid-seizure-
bits>,<cid-lev-
el>,<cid-mode>,<au-
dio-law>]>,<t-dial>,
<t-alert>,<t-con-
nect>,<polarity re-
versal>,<t-reversal>
FXS ports only.
<country-code>
Impedance for individual analog controllers.
0 = General European TBR21 standard (default)
0001 = USA
0049 = Germany
0090 = Turkey
0212 = Marocco
0027 = South Africa
0593 = Ecuador
0961 = Lebanon
0962 = Jordan
0966 = Saudi Arabia
0967 = Yemen
0971 = UAE
<charge-freq>
frequency in kHz of charge impulse: 16 (default) or 12
<cid-T5>
After first ring: pause (in ms) before generation of caller ID
Default: 800
<cid-max-short>
Max duration of short pause (in ms) between first and second ring
Default: 250
<cid-min-long>
Min duration of long pause [ms] between first and second ring
Default: 1500
<cid-seizure-bits>
Length of caller ID signal: 80 (default) or 180
<cid-level>
Caller ID signal level between 0 and 65535
0 = caller ID off
We recommend a value of 12800 (default)
<cid-mode>
Caller ID standard
1 = V.23 (default)
2 = BELL 202 (usuall used in North America)
(continued on next page)
Table 5.15 pabx.cfg: Subscriber Parameters (continued)
Subscriber<port>=<list>

Table of Contents