Installing Topcon Receiver Utility (TRU)
5-1
P/N: 1023998-01
Configuration
The HiPer VR receiver is primarily used for surveying land and construction job sites, and to support
static and RTK applications. You can also log data internally to a non-removable SD card. These logs
can be downloaded from the receiver for static or kinematic surveying, mapping, monitoring, and
positioning applications. The receiver uses different built-in communication technologies to transmit or
receive RTK corrections, and to achieve RTK solutions using field applications like MAGNET Field or
Pocket 3D.
The receiver can be configured in a variety of ways, depending on your project requirements. Typically,
the receiver supports the following operation modes:
Static and kinematic post-processing
Network RTK rover as NTRIP client
UHF/FH base and rover in RTK or DGPS configuration (for receiver with UHF/FH modem)
LongLink base and rover in RTK or DGPS configuration
UHF/FH modem repeater (for receiver with UHF/FH modem)
DGPS or RTK repeater
Precise Point Positioning (PPP) rover
SBAS rover
This chapter describes: receiver configuration, receiver options, loading a new Option Authorization File
(OAF), updating firmware, and performing a factory reset. All these actions may be performed using
Topcon Receiver Utility (TRU) software.
Installing Topcon Receiver Utility (TRU)
TRU is a Microsoft Windows
®
software application designed for configuring GNSS receivers, modem boards, and
Bluetooth modules. This software is available on myTopcon.com for registered users. After downloading the
program from the website, copy the *.zip file into folder on hard drive of controller or computer.
1. Navigate to the folder, and extract the TRU*.zip file.
2. Double-click TRU*.exe to run the installer, and then follow the on-screen instructions.
Loading New Firmware
This section of the configuration chapter describes how to update firmware on the HiPer VR with a USB
connection. To connect the receiver to your computer, use a Micro-USB cable (P/N 1013602-01) and
USB drivers installed on the computer. USB drivers and firmware are available at myTopcon.com.
To uninstall TRU, use Add or Remove Programs in Microsoft Windows.

Table of Contents

Other manuals for Topcon HiPer VR

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Topcon HiPer VR and is the answer not in the manual?

Topcon HiPer VR Specifications

General IconGeneral
Battery LifeUp to 10 hours
Ingress ProtectionIP67
Internal Memory8 GB
Signal TrackingGPS, GLONASS, Galileo, BeiDou, QZSS, SBAS
Static Accuracy Horizontal3 mm + 0.1 ppm
Static Accuracy Vertical5 mm + 0.5 ppm
CommunicationBluetooth, Wi-Fi
Operating Temperature-40°C to +65°C
Update Rate20 Hz