5. SYSTEM MODE EO18-33031
5.4 DIAGNOSTIC
5-19
3CH
4CH
5CH
6CH
7CH
8CH
RETRY POSITION [ ]
[Description] Feed amount to retry data write
[Values to be printed]
-99MM to +99MM
RETRY LABELS [ ]
[Description] The number of RFID labels to be issued for retry
[Values to be printed]
0 to 255 labels
READ RETRY [ ]
[Description 1] The number of times tag read is retried
[Values to be printed 1]
0 to 255 times
[Description 2] Timeout for tag read retry
[Values to be printed 2]
0 to 9.9 sec.
WRITE RETRY [ ]
[Description 1] The number of times tag write is retried
[Values to be printed 1]
0 to 255 times
[Description 2] Timeout for tag write retry
[Values to be printed 2]
0 to 9.9 sec.
POWER LEVEL [ ]
[Description] Radio output level
[Values to be printed]
0 to 18: B-EX706-RFID-U4-EU/US/AU-R, B-EX7060-RFID-U4-R
Q VALUE [ ]
[Description] RFID module Q value
[Values to be printed]
0 to 15
AGC THRESHOLD [ ]
[Description] AGC threshold setting
[Values to be printed]
0 to 15
WRITE AGC [ ]
[Description] AGC threshold for data write
[Values to be printed]
0 to 15
RETRY MIN AGC [ ]
[Description] AGC threshold lower limit for retry