8. AUTO CONFIGURATION MODE EM18-33031
8.1 OUTLINE OF THE AUTO CONFIGURATION MODE
8-1
8. AUTO CONFIGURATION MODE
8.1 OUTLINE OF THE AUTO CONFIGURATION MODE
When turning on the printer while holding down the [CANCEL] key, the printer to start auto configuration
mode.
The auto configuration mode allows for automatically downloading the master firmware and restarting the
printer.
Power OFF (1) Power off state
[CANCEL]
(2) Turn on the printer while holding down the [CANCEL]
key.
(3) Auto configuration mode display
[PAUSE]/[MODE]/
[CANCEL]/[ENTER]
(4) Press the [PAUSE], [MODE], [CANCEL] or [ENTER]
key to show the next display.
(5) Confirmation display
[ENTER]
(6) Select “OK” and press the [ENTER] key.
* When “CANCEL” is selected, the printer returns to the
online state without downloading the firmware.
(7) The firmware is being downloaded.
(8) After downloading is completed, the printer will return
to the online state.
8.2 PREPARATION FOR USB MEMORY
To execute the auto configuration mode, the firmware file (*.bin) should be downloaded and the
dedicated CFG file need to be created in the USB memory in advance. To enter the auto configuration
mode, the RTCUSB host, USB memory, correct CFG file need to be all prepared. Lack of any one of
these disables shifting to the auto configuration mode, but starts normally.
Each file is saved in the SYSTEM directory created in the root directory in the USB memory.
Example: When BOOT/MAIN/CG programs are downloaded:
/ATA0/SYSTEM/B-EX-BOOT-Vx.x-xx.bin
/ATA0/SYSTEM/B-EX-MAIN-Vx.x-xx.bin
/ATA0/SYSTEM/B-EX-CG-Vx.x-xx.bin
/ATA0/SYSTEM/AUTOCONFIG.CFG