11. DISPLAY PATTERN AND KEY OPERATION FOR SYSTEM MODE AND USER SYSTEM MODE EM18-33031
11.2 VALUE SETTING SCREEN
11-5
11.2 VALUE SETTING SCREEN
The value setting screen is used for setting a value by increasing or decreasing it.
It is comprised of the following parts.
Display example
FEED ADJ.
+0.0 mm
(-50.0 - +50.0)mm
NOTES:
1. The currently programmable item is highlighted.
2. The display of the symbols like “+” and “-“, and the unit of measure like “mm” and “step” differs depending on
the item to be set.
Display
Setting screen with one field
FEED ADJ.
+0.0 mm
(-50.0 - +50.0)mm
Setting screen with multiple fields (placed
horizontally)
IP ADDRESS
192 .168 .010 .002
Setting screen with multiple fields (placed
vertically)
READ RETRY
5 times
4.0 sec
( 0.0 - 9.9 )sec
( 0 - 255 )times
Key function (Setting screen with one field)
Key Substitute Key Function
[MODE] None Returns to the top menu without saving changes.
[CANCEL] [FEED] + [RESTART] Returns to the upper-level menu without saving changes.
[ENTER] [PAUSE] Saves the changes and returns to the upper-level menu.
[UP] [RESTART] Increases the setting value by specified step. When the setting
value reaches the maximum, it returns to the minimum value
and increases.
[DOWN] [FEED] Decreases the setting value by specified step. When the
setting value reaches the minimum, it returns to the maximum
value and decreases.
[LEFT] None No function
[RIGHT] None No function
Setting value
Setting range
Title

Table of Contents