5. SYSTEM MODE EM18-33031
5.5 SET PARAMETERS
5-35
5.5.21 FEED ADJ.
Max.
value
Min. value Step Display Sign
Integer
digit
Decimal
place
0-padding
Unit of
measure
+50.0 -50.0 0.1 Decimal Exist 2 1 None mm
NOTES:
1. The feed amount fine adjustment value is the sum of the fine adjustment values set in the system mode (by key
operation) and set by command (from the PC). The max. value is ±50.0mm.
2. A value which is equal to or larger than the media pitch (FEED ADJ. ≥ Media pitch) must not be set. If the set fine
adjustment value causes the printer to feed the media backward from the print stop position to the next print start
position, the printer operation is not guaranteed.
+0.0 mm
+3.0 mm
Print start
position
One label
One label
Print start
position
-3.0 mm
One label
Print start position
Paper feed direction