5. SYSTEM MODE EM18-33031
5.8 RAM CLEAR
5-55
<Reference: Maintenance counter printout>
<< COUNTER >>
TOTAL FEED 4.8km [QM]
FEED 0.0km ··· Label distance covered
FEED1 4.8km
FEED2 0.0km
FEED3 0.0km
FEED4 0.0km
PRINT 0.0km ···
Print distance
PRINT1 4.5km
PRINT2 0.0km
PRINT3 0.0km
PRINT4 0.0km
CUT 0 ·········
Cut count
HEAD U/D 0 ·········
Head up/down count
RIBBON 0h ······· Ribbon motor drive time
SOLENOID 0h ······· Head-up solenoid driver time
232C ERR 0 ·········
RS-232C hardware error count
SYSTEM ERR 0 ········· System error count
POWER FAIL 0 ········· Momentary power interruption count
2. LCD message while a maintenance counter clear is performed
Display
While clearing
ALL COUNTER
CLEAR...
After the maintenance counter
clear is completed
ALL COUNTER
COMPLETED
Turn off the printer
3. After the maintenance counter clear is completed, turn off the printer when “COMPLETED. Turn off the
printer” is displayed.
5.8.3 PARAMETER CLEAR
The parameter settings are cleared and reset to the initial values for each destination.
When the printer is started for the first time after a parameter clear, the initial setting wizard is started.
This wizard enables setting the basic parameters (LCD language, use of the ribbon, media type, etc.)
required for various settings.
5.7.4.3 Parameters to be Cleared
After the parameter settings are cleared, the initial values for a selected destination are set.
QM TYPE
JA TYPE
CN TYPE