10. ON LINE MODE EM18-33031
10.6 MANUAL THRESHOLD SETTING
10-12
6c. Threshold fine
adjustment
THRESHOLD <REFL.>
1.0 V
( 0.0 - 4.0 V)
Operation is same as 9.7.4
THRESHOLD LEVEL.
Press any of the [PAUSE], [ENTER], and [CANCEL] key.
6d. Judgment result (After
the fine adjustment)
1)REFL.(PRE-PRINT)
Result: OK (Mid.)
Threshol
Baseline
◀Adjust Detail▶
[LEFT] key “6c. Threshold fine adjustment.” (The threshold value is fine adjusted again.)
[ENTER] key “2. Pause state.” (Threshold setting is completed.)
[RIGHT] key “6b.
Details of the result.” (Result and the threshold value are displayed.)
7. Threshold setting:
7a. Judgment result (NG)
1)REFL.(PRE-PRINT)
Result: Failed (1)
Threshol
Baseline
Retry FEED Detail▶
×
×
[FEED] key “3. Media sensor selection.” (Threshold is set again.)
[ENTER] key “2. Pause state.” (Threshold setting is completed.)
[RIGHT] key “7b. Details of the result.” (Result and the threshold value are displayed.)
7b. Details of the result
1)REFL.(PRE-PRINT)
Peak : 2.1V
Threshold : 1.3V
Baseline : 1.2V
◀Result
[LEFT] key: Go to “7a. Judgment”