4. INSTALLATION PROCEDURE FOR OPTIONAL EQUIPMENT EO18-33031
(Revision Date: Mar. 1, 2017)
4.8 UHF RFID KIT (B-EX706-RFID-U4-US/EU/AU-R)
4-59
3) Set an AGC threshold of data write.
Set a value which is lower than the AGC value by 1 or 2, taking variation of RFID tags in performance into
consideration.
(1) Choose “UHF SETTING”, and press the [ENTER] key.
(2) Choose “WRITE AGC THRESHOLD”, and press the [ENTER] key.
(3) Set a threshold value with [UP] or [DOWN] key, then press the [ENTER] key.
When the measured AGC was 9, for example, set “8” (a value lower than the measured AGC by 1
or 2.)
(4) Choose “WRITE RETRY MIN AGC”, and press the [ENTER] key.
(5) Set a lower limit with the [UP] or [DOWN] key.
Usually, set the same value with the AGC threshold for data write (WRITE AGC THRESHOLD).
In the case of this example, set “8” and press the [ENTER] key.
(6) AGC threshold setting is completed.
Reference: Recommended setting for RFID tag and Label (Example)
B-EX6T1, Recommended setting for RFID Tag and Label
Answer date 5/Sep/2016
Basic
Information
Dealer/SI XXXXXXXX End User YYYYY
Label Manufacturer ZZZZ Label Size W 80mm X L 60mm Gap 5 mm
Antenna Position F / C / R
Kinds of sealed label F / C / R
Antenna sealed sheet Need / No need
Printer
setting
Retry The adjustment for reprinting +3mm
The number of re print 3
Reading try 5 times 4.0s
Writing try 5 times 2.0s
UHF Output level 13
Q value 2
Tag performance judgment 10
The performance threshold
for writing
10
The performance threshold
for writing(Lower limit)
10
Application
setting
Writing position(@0003)
Remarks
These values need to be
set in the SYSTEM mode.
RFID setting.
(Caution)
These values are different
depending on the tag
used.