EasyManua.ls Logo

TSC TTP-244 Plus

TSC TTP-244 Plus
252 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TSC AUTO ID Technology Co., Ltd. 216 Copyright 2013 All Rights Reserved.
MINUTE
Description
This variable reads/writes the minute data via the Real Time Clock (RTC). Two-digits (00~59) minute
format is supported by RTC.
Syntax
Write attribute: MINUTE = 12
Read attribute: A = MINUTE
Range: 00~59
Example
Sample code
DOWNLOAD "SetMinute.BAS"
REM *****Set Minute Parameter to RTC*****
MINUTE=27
EOP
SetMinute
Sample code
DOWNLOAD "DEMO.BAS"
SIZE 4,1
GAP 0,0
DIRECTION 1
CLS
REM *****Read Minute parameter form RTC*****
MINUTE$=STR$(MINUTE)
MIN=MINUTE
REM *****Print*****
TEXT 10,10,"3",0,1,1,"MINUTE1="+MINUTE$
TEXT 10,50,"3",0,1,1,"MINUTE2="+STR$(MIN)
TEXT 10,90,"3",0,1,1,"MINUTE3="+STR$(MINUTE)
PRINT 1
EOP
DEMO
Result
See Also
~!C, MONTH, DATE, DAY, HOUR, MINUTE, SECOND

Table of Contents

Other manuals for TSC TTP-244 Plus

Related product manuals