6 Useful Functions
98
Useful Functions
Chapter
6
Holding register
Set point 1 Indicates SP1. (0 to 99999)
Set point 2 Indicates SP2. (0 to 99999)
Final Indicates final. (0 to 99999)
Auto free fall compensation
regulation value
Indicates auto free fall compensation regulation value.
(0 to 99999)
Upper limit Indicates upper limit. (0 to 99999)
Lower limit Indicates lower limit. (0 to 99999)
Near zero Indicates near zero. (0 to 99999)
Weighing function 2 I
ndicates weighing function 2.
Tare setting Indicates tare setting. (0 to 99999)
Balance weight value Indicates valance weight value. (0 to 99999)
Capacity Indicates capacity. (0 to 99999)
Net over Indicates net over. (0 to 99999)
Gross over Indicates gross over. (0 to 99999)
Equivalent calibration
Indicates the equivalent calibration value.
(0.1000 to 3.2000)
D/A zero output weight value D/A zero output weight v
alue (0 to 99989)
D/A full scale setting D/A full scale setting (1 to 99999)
Extended function selection 1 Indicates extended function selection 1
Input selection Indicates input selection.
Average weight Indicates average weight. (read only) (0 to 99999)
Max. weight Indicates max. weight. (read only) (0 to 99999)
Min. weight Indicates min. weight. (read only) (0 to 99999)
Gen. stan. dev. Indicates gen. stan. d
ev. (read only) (0 to 99999)
Smp. stan. dev. Indicates smp. stan. dev. (read only) (0 to 99999)
Max. - min. Indicates max. - min. (read only) (0 to 99999)
Latest accumulation data
Indicates the latest accumulation data. (read only)
(0 to 99999)
Accumulated value
Indicates the accumulated value. (read only)
(0 to 999999999)
Compensation Indicates the compensation. (0 to 9999)
Over Indicates over. (0 to 999)
Unde
r Indicates under. (0 to 999)
Comparison inhibit time Indicates comparison inhibit time. (0 to 999)
Judging time Indicates judging time. (0 to 999)
Complete output time Indicates complete output time. (0 to 999)
Compensation feeding time Indicates compensation feeding time. (0 to 999)
AZ times Indicates the number of times for AZ. (0 to 99)
Number of times for judging Indicates judging time. (0 to 99)
Weighing
function 1 Indicates weighing function 1.
Weighing function 3 Indicates weighing function 3.
Sequence mode Indicates sequence mode.
Function key inhibited Indicates function key inhibited
Filter Indicates filter.
MD (time - range) Indicates MD (time - range). (00-00 to 99-99)*6
ZT (time - range) Indicates ZT (time - range). (00-00 to 99-99)*6
DZ regulation value Indicates DZ regulation value. (0 to 9999)
Function
selection Indicates function selection.
Compensation for gravitational
acceleration
Indicates compensation for gravitational acceleration.
(97500 to 98500)
D/A output mode Indicates D/A output mode.
Moving average filter Indicates moving average filter.
Measurement Act compliance Indicates Measurement Act compliance.
Output selection Indicates output selection.
Restart setting Set point 1 Indicates restart set
ting, set point 1. (0 to 100)
Restart setting Set point 2 Indicates restart setting, set point 2. (0 to 100)
Restart setting Set point 3 Indicates restart setting, set point 3. (0 to 100)
Number of times for knocking Indicates number of times for knocking. (0 to 99)
Knocking time Indicates knocking time. (0 to 99)
Number of digits for accumulated
display
Indicates number of digits for accumulated display. (5
to
9)
Min. scale division Indicates min. scale division. (1 to 100)
Setting value LOCK Indicates setting value LOCK.
Number of data Indicates number of data. (read only)