EasyManuals Logo

Unipulse F701+ User Manual

Unipulse F701+
149 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #124 background imageLoading...
Page #124 background image
117
6 Useful Functions
117
Useful Functions
Chapter
6
4. When turning OFF the command bit immediately after execution, do so after confirming the
response in "3".
Commands which detect OFF edges and OFF levels do not require a reset to the previous status.
5. When the command bit is turned OFF, the corresponding command response will also be turned
OFF.
Example 1) Performing one-touch tare subtraction
Example 2) Starting hold by giving ON edge to hol
d command bit,
and then releasing hold by giving OFF edge.
- When performing commands by command bits, be sure to check the status of the
corresponding command bit response prior to making changes. (If the ON/OFF
level of the bit does not change, the command will not be performed on the F701+
side.)
- Perform commands by command bits one by one, following the procedure, and do
not perform multiple commands at once.
- Remote READY may not be ON immediately after po
wer ON. In such cases, wait
until it turns ON before performing the procedure.
Attention
Command bit
(One-touch tare subtraction)
Command bit response
(One-touch tare subtraction response)
One-touch tare subtraction process
Net weight
Remote READY
ON
Execute
Hold start/release process
Gross weight
Remote READY
ON
Hold release Hold release
Command bit
(Hold)
Command bit response
(Hold response)