134
8 List of Setting Items
134
List of Setting Items
Chapter
8
■Setting mode 5
■Setting mode 6
■Setting mode 7 (with RS-232C option)
Name
Initial
value
Setting range
Lock1
(soft)
Lock2
(soft)
LOCK
(SW)
Display
only
Communication
command
1 Input selection 93210 00000 to 99999
◎
W60(R/W)
Input selection 5 9 9: Tare reset
8: Pause
7: Erase print
6: Total print
5: Accumulation clear
4: Accumulation command
3: Stop
2: Start
1: Feed/discharge
0: Hold/judge
Input selection 4 3
Input selection 3 2
Input selection 2 1
Input selection 1 0
2 Output selection 0
3: Knocking
2: Waiting for judgment
1: Pause
0: RUN
◎
W61(R/W)
3 Restart settingSet point 1 100 000
to 100
◎
W62(R/W)
4 Restart settingSet point 2 100 000 to 100
◎
W63(R/W)
5 Restart settingSet point 3 100 000 to 100
◎
W64(R/W)
6 Number of times for knocking 00 00 to 99
◎
W65(R/W)
7 Knocking time 0.00 0.00 to 9.99
◎
W66(R/W)
8
Number of digits for
accumulated display
5 5 to 9
◎
W67(R/W)
9 Automatic filter adjustment 0
1: Execute
0: Cancel
◎
Name
Initial
value
Setting range
Lock1
(soft)
Lock2
(soft)
LOCK
(SW)
Display
only
Communication
command
1 PROFIBUS I/F setting 00 00 to 01
◎
2 PROFIBUS baud rate display ----
◎
3 PROFIBUS station no. 125 000 to 125
◎
4
◎
5
◎
6
◎
7
◎
8
◎
9
◎
Name
Initial
value
Setting range
Lock1
(soft)
Lock2
(soft)
LOCK
(SW)
Display
only
Communication
command
1 Print setting 1010 0000 to 1010
◎
W70(R/W)
Automatic print 1
1: ON (manual print OFF)
0: OFF (manual print ON)
Undefined 0
Near zero print 1 1: ON 0: OFF
Undefined 0
2 Printer command 0
4: Paper feed
3: Date print
2: Erase print
1: Total print
0: Clear
◎
Comma
nd