Introduction
3
Regulatory Compliance and Approvals
Plan your leak detection program to comply with local, state, and federal regulations governing underground storage
tanks. Save all inventory and leak test records provided by the system as part of a regulatory compliance program.
The system, when equipped with 0.2 gallon-per-hour (gph) (0.76 lph) (Mag 2) probes, is classified as an Automatic
Tank Gauge System and has been third-party tested by Midwest Research Institute. This system can detect a 0.2 gph
leak exceeding a 95% probability of detection [P(D)] and less than a 5% probability of false alarm [P(FA)]. It meets
federal U.S. E.P.A. performance standards (0.2 gph at [P(D)] of 95% and [P(FA)] of 5%) and the federal performance
standard of measuring water in the bottom of a tank to the nearest 1/8 inch (3.2 mm).
The system, when equipped with 0.1 gph (0.38 lph) (Mag 1) probes, meets Volumetric Tank Tightness Testing Method
standards and has been third-party tested by Midwest Research Institute. This system can detect a 0.1 gph leak
exceeding a 95% probability of detection [P(D)] and less than a 1% probability of false alarm [P(FA)]. This system
meet U.S. E.P.A. federal performance standards (0.1 gph at [P(D)] of 95% and [P(FA)] of 5%).
Console
The TLS2P Console features a front panel touch screen display, a dual-purpose Alarm/Normal LED, and an audible
beeper for alarm and warning notification. A serial communication port is available for output to a remote printer. The
TLS2P Console can monitor up to six magnetostrictive probes.
MONITORING FUNCTIONS
Depending on installed equipment, the console can provide:
Inventory status for up to six tanks
In-tank leak detection.
OUTPUT RELAY
An output relay is provided that can trigger external alarm devices when an alarm condition is sensed by the system.
COMMUNICATIONS FUNCTIONS
Several communications options are available for the TLS2P Console:
•RS-232
•RS-422
RS-485 2-wire or 4-wire
External modem support
Serial remote printer interface
•USB (DEVICE ONLY)
•TCP/IP