Communication Interfaces
VTK-TR-BA-072e-1 - User Manual MDS 358X Series
10 HEATER:?
This command shows the state of the heater. This includes the following
information.
• T-point of the temperature calibration
• M- point of the temperature calibration
• Maximum temperature of the connected heater (°C)
• the current target temperature (°C)
• upper limit of allowed temperature range (°C x 10)
• lower limit of allowed temperature range (°C x 10)
• current temperature (°C)
• calibration status (0 = no, 1 = yes)
• current heater status (1 = ON, 2 = OFF, 4 = not
calibrated, 5 = temperature settled in, 7 = plugged in,
8 = plugged out, 9 = calibration 20 °C, 10 =
calibration 100 °C; XXXX communication error code)
In case there is no heater connected, the response is “NAK”.
Switched ON or OFF, current temperature and target
temperature and other information are given.
1000, 20000, 180, 110, 30, 20, 109, 1, 5
11 HEATER:ID?
This command shows the type and serial number of the heater.
In case there is no heater connected, the response is “NAK”.
Type and serial number of the heater are given.
12 HEATER:OFF
The connected heater is turned off.
In case there is no heater connected, the response is “NAK”.
The connected heater is deactivated.
13 HEATER:ON
The connected heater is turned on.
In case there is no heater connected, the response is “NAK”.
The connected heater is activated.