Communication Interfaces
VTK-TR-BA-072e-1 - User Manual MDS 358X Series
26 MAINT:STATUS MAINT = Maintenance
This command provides the number of pulses in percent of the preset
limits. It is useful, if you want to estimate the date of the next exchange or
maintenance.
The answer will be send in one line.
Current percentage of the preset number of cycles (limit).
Maintenance: 10 %,Nozzle: 20 %,Tappet: 30 %,Maint.
Message: ON
27 MAINT:MESSAGE:OFF (MAINT = Maintenance)
This command deactivates the maintenance message.
The message “Maint.” will no longer be shown in line 2 of the display. Also
the red maintenance LED will not be switched on, if the maintenance,
nozzle or tappet limits are reached.
By default, the maintenance message is activated.
The maintenance message is deactivated.
28 MAINT:MESSAGE:ON (MAINT = Maintenance)
This command activates the maintenance message.
The message “Maint.” will be shown in line 2 of the display. Also the red
maintenance LED will be switched on, if the maintenance, nozzle or tappet
limits are reached.
By default, the maintenance message is activated.
The maintenance message is activated.