Communication Interfaces
VTK-TR-BA-072e-1 - User Manual MDS 358X Series
29 SYSTEM:KLOCK:OFF (KLOCK = Key Lock)
Access to keypad is permitted, the locking function disabled.
The keypad of the control unit can be used.
30 SYSTEM:KLOCK:ON (KLOCK = Key Lock)
This command locks the keypad of the control unit. This way, unauthorized
modification of parameters can be prevented.
31 SYSTEM:SHOW:CYCLES
The current value of the cycle counter is indicated.
Current value of the cycle counter.
32 SYSTEM:SHOW:VALVEID
The valve ID is displayed.
In case the system is in auxiliary mode, the return is “Auxiliary Mode”.
ID of the connected valve.
33 SYSTEM:SHOW:CONTROLLERID
The ID of the control unit is displayed.
34 SYSTEM:SHOW:STATUS
This command sends the current status of KeyLock, DosOK with Delay,
SingleDosOK and Auxiliary Mode.
Settings of the above listed items
DosOK with Delay: OFF
SingleDosOK: per pulse