Communication Interfaces
96
VTK-TR-BA-072e-1 - User Manual MDS 358X Series
29 SYSTEM:KLOCK:OFF (KLOCK = Key Lock)
Description:
Access to keypad is permitted, the locking function disabled.
Example:
Input:
SYSTEM:KLOCK:OFF
Result:
The keypad of the control unit can be used.
Return:
OK
30 SYSTEM:KLOCK:ON (KLOCK = Key Lock)
Description:
This command locks the keypad of the control unit. This way, unauthorized
modification of parameters can be prevented.
Example:
Input:
SYSTEM:KLOCK:ON
Result:
The keypad is locked.
Return:
OK
31 SYSTEM:SHOW:CYCLES
Description:
The current value of the cycle counter is indicated.
Example:
Input:
SYSTEM:SHOW:CYCLES
Result:
Current value of the cycle counter.
Return:
1235000
32 SYSTEM:SHOW:VALVEID
Description:
The valve ID is displayed.
In case the system is in auxiliary mode, the return is Auxiliary Mode”.
Example:
Input:
SYSTEM:SHOW:VALVEID
Result:
ID of the connected valve.
Return:
Valve ID: 10PEA001
33 SYSTEM:SHOW:CONTROLLERID
Description:
The ID of the control unit is displayed.
Example:
Input:
SYSTEM:SHOW:CONTROLLERID
Result:
ID of the control unit.
Return:
Controller ID: 13050
34 SYSTEM:SHOW:STATUS
Description:
This command sends the current status of KeyLock, DosOK with Delay,
SingleDosOK and Auxiliary Mode.
Example:
Input:
SYSTEM:SHOW:STATUS
Result:
Settings of the above listed items
Return:
KeyLock: OFF
DosOK with Delay: OFF
SingleDosOK: per pulse
Auxiliary Mode: OFF