35 SYSTEM:SHOW:ACTTEMP
The current temperature of the actuator (piezo) is displayed.
NOTE:
In case an MFC is connected to your MDC, you cannot use this command,
since it would respond with a wrong value.
36 SYSTEM:DOSOKDELAY:OFF
This command deactivates the DOSOK-Delay.
When this is true, the length of a delay is not added to the length of the
Deactivates the DOSOK-delay.
37 SYSTEM:DOSOKAYDELAY:ON
This command activates the DOSOK-Delay.
When this is true, the length of a delay is added to the length of the DOSOK
Activates the DOSOK-delay.
38 SYSTEM:SINGLEDOSOK:SETUP
This command sets the Single-DOSOK signal to “Setup”. The length of the
Single-DOSOK signal is that of the setup. (Default setting is “Pulse”.)
The Single-DOSOK is set to “setup”.
39 SYSTEM:SINGLEDOSOK:PULSE
This command sets the Single-DOSOK signal to “Pulse”. The length of the
Single-DOSOK signal is that of a pulse. (Default setting is “Pulse”.)
The Single-DOSOK is set to “pulse”.