Global Setup Menu Functions
TVM Series Installation and Operation Handbook 155
Copyright © 2008, Harris Corporation
Table 4-10. Time Code Alarms Menu
Selection Selection Option Selection Option
ALARM REPORTING
SETUP
MATRIX SCREEN -
OFF (Default) ENABLE
ON
LTC LOSS OF TIME
CODE
DURATION 0 TO 600 SECONDS
(240 Seconds is Default)
OFF (Default) ENABLE
ON
RANGE 0.4 TO 2 VOLTS (0.5 is
Default)
LTC TIME CODE
LEVEL
DURATION 0 TO 600 SECONDS
(240 Seconds Default)
OFF (Default) ENABLE
ON
RANGE 1.5 TO 10.5 LINES
LTC TIME CODE
FRAMING
DURATION 0 TO 600 SECONDS
(240 Seconds Default)
OFF (Default) LTC TIME CODE
CONTINUITY
ENABLE
ON
OFF (Default) ENABLE
ON
THRESHOLD 1 TO 30 FRAMES (1
Frame is Default)
LTC/DVITC
COMPARE (TC
SYNC)
DURATION 0 - 60 SECONDS (2
Seconds is Default)
OFF (Default) ENABLE
ON
D-VITC LOSS OF
TIME CODE
DURATION 0 TO 600 SECONDS
(240 Seconds Default)
OFF (Default) ENABLE
ON
LINE 525 525 LINE:
10 TO 30 LINES
(LINE 14 is Default)
LINE 625 625 LINE:
6 TO 30 LINES
(LINE 14 is Default)
D-VITC LINE
DURATION 0 TO 600 SECONDS
(240 Seconds Default)
OFF (Default) D-VITC CONTINUITY ENABLE
ON
D-VITC CRC ENABLE OFF (Default)