July 2019
2-12
Xerox® B210 Service Manual
09-400 , 09-500
Initial Release
Status Indicator RAPs
09-400 Imaging Unit End of Life RAP
The Imaging Unit has reached end of life.
Procedure
1. Check the remaining life of the Imaging Unit by using one of the methods listed below:
• Print a Supplies Information Report, GP
 2.
• Open Easy Printer Manager, select [Machine Status].
• Open the CWIS application. Select; [S
tatus, Supplies, Black Imaging Unit].
NOTE: The workstation and printer machine must be networked to use the CWIS
applicat
ion.
2. Check the remaining life of the Imaging Unit.
3. If the Imaging Unit has reached end of life, Switch off the machine and Install a new Imag-
ing Unit.
09-500 Toner Cartridge Not Installed RAP
BSD-ON:BSD 1
The Toner Cartridge has not been installed or machi
ne software is unable to detect the Toner 
Cartridge. 
Initial Actions
Ensure that the Toner Cartridge has been installed and the cover is fully closed and latched.
Procedure
1. Switch off the machine.
2. Remove the Toner Cartridge. Rotate the cartridge five to six completions to distribute t
he
t
oner evenly.
3. Check the CRUM contact area for contamination and clean if necessary.
4. Reinstall the Toner Cartridge.
5. Check the connections on the HVPS for contamination. Clean as necessary.
6. If the fault persists, install a new Toner Cartridge.