08/2012
6-57
WorkCentre 5021/5019
6.3.11
General Procedures
Initial Issue
6.3.11 NVM Xfer
Table 1 NVM Xfer
Chain-Link NVM Name
Setting
Range
(Minimum
Value)
Setting
Range
(Maximum
Value)
Default
Value
Write
Yes/No
Initialization
Yes/No Description
745-015 XERO_TEMP_DATA -20 60 18 Enable Enable Stores the temperature detection result.
(Unit: 1 degrees C)
745-097 XERO_BTR_OUTPUT_SIDE1_BIAS 0 200 80 Enable Enable Stores the BTR Output (Side 1)
(Unit: 0.1 MicroAmp)
745-098 XERO_BTR_OUTPUT_SIDE2_BIAS 0 200 80 Enable Enable Stores the BTR Output (Side 2)
(Unit: 0.1 MicroAmp)
745-100 XERO_BTR_CORR_COEF_PLAIN_SIDE1 0 200 100 Enable Enable BTR Output Correction Coefficient (for Plain Side 1)
(Unit: %)
745-101 XERO_BTR_CORR_COEF_PLAIN_SIDE2 0 200 100 Enable Enable BTR Output Correction Coefficient (for Plain Side 2)
(Unit: %)
745-102 XERO_BTR_CORR_COEF_HEAVY_SIDE1 0 200 100 Enable Enable BTR Output Correction Coefficient (for Heavyweight Side 1)
(Unit: %)
745-103 XERO_BTR_CORR_COEF_HEAVY_SIDE2 0 200 100 Enable Enable BTR Output Correction Coefficient (for Heavyweight Side 2)
(Unit: %)
745-104 XERO_BTR_NET_OUTPUT_SIDE1_BIAS 0 200 80 Enable Enable Stores the BTR Final Output (for Side 1)
(Unit: 0.1 MicroAmp)
745-105 XERO_BTR_NET_OUTPUT_SIDE2_BIAS 0 200 80 Enable Enable Stores the BTR Final Output (for Side 2)
(Unit: 0.1 MicroAmp)