EasyManua.ls Logo

Xerox WorkCentre 5021 - Controller Backup NVM Data Defect

Xerox WorkCentre 5021
457 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
08/2012
2-53
WorkCentre 5021/5019
117-326
Status Indicator RAPs
Initial Issue
117-326 Controller Backup NVM Data Defect
BSD-ON:-
Any of the following was detected:
The Backup NVM data of the Controller is corrupted.
The Backup NVM of the Controller is not installed.
Any one of the Print Counter has reached its maximum value.
The number of times the NVM can be changed has reached its limit.
Cause/Action
1. Turn the power OFF and ON.
2. Check the EEPROM (Master) on the ESS/MCU PWB for poor contact with the socket.
3. Perform NVM Initialize in the CE Mode. (Refer to [6.4.2.5 NVM Initialize].)
4. If the problem persists, replace the ESS/MCU PWB. (PL 18.1)

Table of Contents

Other manuals for Xerox WorkCentre 5021

Related product manuals