Hardware Installation Manual ADPRO
®
FastTrace™ 2 Series
90 21790_05
(*) Some PIR models have separate 0V terminals for data and power; on other models there is only one
common 0V terminal.
The PIRs are powered locally by a power adapter.
You can place locally powered PIR detectors at the maximum distance of 1200 m for RS-485 cables, but
remember that this remains a 3-line communication (RS-485 + 0V).
Make sure that there is no difference in earth potential between the server and the PIR.
18.2.1.1 Main I/O Cards Next Generation
On the MIO card Next Generation, all connectors are available, so you do not need to adjust any jumpers to
choose between PTZ and audio output. Set the RS-485 PTZ jumper to the 2-wire (PTZ) position.
MIO card Next Generation
E
RS-485 PTZ jumper: 4-wire setting
(default setting)
F
RS-485 PTZ jumper: 2-wire setting
Connect the cables as shown below.