6F65G11
2-6
9
8
7
6
5
4
3
2
1
Maintenance specification
Item Unit
Model
E40GMH E40GWH E40JMH E40JWH E40JW
CDI unit output peak voltage
(O–B)
at Cranking (loaded) V 160
at 1,500 r/min (loaded) V 185
at 3,500 r/min (loaded) V 170
Pulser coil output peak voltage
(W/R–B, W/B–B)
at Cranking (unloaded) V 10.0
at Cranking (loaded) V 10.0
at 1,500 r/min (loaded) V 30.0
at 3,500 r/min (loaded) V 66.0
Pulser coil resistance (W/R–B) 16.2–19.8
Pulser coil resistance (W/B–B) 16.2–19.8
Charge coil output peak
voltage (Positive side: Br–
Negative side: L)
at Cranking (unloaded) V 150
at Cranking (loaded) V 140
at 1,500 r/min (loaded) V 190
at 3,500 r/min (loaded) V 180
Charge coil resistance (Br–L) 243–297
Starter motor
Type
Brushes Bendix Bendix
Length limit mm (in)
9.0 (0.35)
9.0 (0.35)
Armature
Commutator undercut limit mm (in)
0.2 (0.01)
0.2 (0.01)
Charging system
Fuse A 20 20
Lighting coil output peak
voltage (G–G)
at Cranking (unloaded) V 6.0
at 1,500 r/min (unloaded) V 17.0
at 3,500 r/min (unloaded) V 38.0
Lighting coil resistance (G–G)
0.32–0.39
Rectifier output peak voltage
(R–B)
at 1,500 r/min (unloaded) V 13
at 3,500 r/min (unloaded) V 13

Table of Contents