Continued on next page.
No.
n.X
Low Battery Voltage Alarm/Warning Selection Reference
0 Output alarm (A.830) for low battery voltage.
*1
1 Output warning (A.930) for low battery voltage.
n.X
Function Selection for Undervoltage Reference
0 Do not detect undervoltage.
*1
1 Detect undervoltage warning and limit torque at host controller.
2
Detect undervoltage warning and limit torque with Pn424 and
Pn425 (i.e., only in SERVOPACK).
n.X
Warning Detection Selection Reference
0 Detect warnings.
*1
1 Do not detect warnings except for A.971.
n.X Reserved parameter (Do not change.)
n.X Reserved parameter (Do not change.)
n.X
Current Control Mode Selection
0
Use current control mode 1.
*1
1
2 Use current control mode 2.
n.X
Speed Detection Method Selection Reference
0 Use speed detection 1.
*1
1 Use speed detection 2.
n.X Reserved parameter (Do not change.)