7.2 List of Servo Parameters
7-43
Pn81E
2
Input Signal Monitor
Selections
0000h to
AAAAh
0000h All
Immedi-
ately
Setup
*13
Pn81F
2
Command Data Alloca-
tions
0000h to
1111h
0010h All
After
restart
Setup
*13
Pn820 4 Forward Latching Area
-2,147,483,648
to
2,147,483,647
1 refer-
ence
unit
0All
Immedi-
ately
Setup
*2
Pn822 4 Reverse Latching Area
-2,147,483,648
to
2,147,483,647
1 refer-
ence
unit
0All
Immedi-
ately
Setup
*2
Continued on next page.
Continued from previous page.
Parameter
No.
Size
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
M2
*13
n.X
IO12 Signal Mapping
0Do not map.
1 Monitor CN1-1 input terminal.
2 Monitor CN1-2 input terminal.
3 Monitor CN1-3 input terminal.
4 Monitor CN1-4 input terminal.
5 Monitor CN1-5 input terminal.
6 Monitor CN1-6 input terminal.
7 Monitor CN1-11 input terminal.
8 Monitor CN1-12 input terminal.
9 Monitor CN1-13 input terminal.
A Monitor CN1-14 input terminal.
B Monitor CN1-15 input terminal.
C Monitor CN1-16 input terminal.
n.X
IO13 Signal Mapping
0 to C The mappings are the same as the IO12 signal mappings.
n.X
IO14 Signal Mapping
0 to C The mappings are the same as the IO12 signal mappings.
n.X
IO15 Signal Mapping
0 to C The mappings are the same as the IO12 signal mappings.
M2
*13
n.X
Option Field Allocation
0 Disable option field allocation.
1 Enable option field allocation.
n.X
Position Control Command TFF/TLIM Allocation
0 Disable allocation.
1 Enable allocation.
n.X Reserved parameter (Do not change.)
n.X Reserved parameter (Do not change.)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA SIGMA-7 Series and is the answer not in the manual?

YASKAWA SIGMA-7 Series Specifications

General IconGeneral
Encoder Resolution24-bit absolute encoder
Pollution Degree2
Cooling MethodNatural cooling or forced air cooling
Control MethodVector control
Communication ProtocolsEtherCAT, MECHATROLINK-III
Input VoltageAC 200 V, AC 400 V
Rated OutputVaries by model
Safety FunctionSTO (Safe Torque Off), SS1 (Safe Stop 1), SS2 (Safe Stop 2), SLS (Safely Limited Speed), SBC (Safe Brake Control)
Power Supply VoltageAC 200 V, AC 400 V
Rated Output CurrentVaries by model
Protection FunctionsOverload, overvoltage, undervoltage, overheat, short circuit
Operating Temperature0°C to 55°C
Storage Temperature-20°C to 65°C
Vibration Resistance5.9 m/s² at 10 Hz to 55 Hz
Ambient Humidity5% to 95% RH (non-condensing)
AltitudeUp to 1000 m
InstallationPanel mounted