ZXR102900SeriesUserManual
CommandFunction
zte(cfg)#setethernet-oamport
<portlist>link-monitorsymbol-period
threshold<1-65535>window
<1-65535>
Thisconguresthe
symbolperiodevent
whichisusedforlink
monitor .
Thesymbolperiodisdecidedbythesymbolnumberwhichis
receivedduringaspeciedperiodbyswitch,thatis,aperiod
istocollectaspeciednumberofsymbols.Whentheerror
symbolnumberislargerthantheperiodreceivingthreshold,
thelinkalarmwillbeappeared.
Theparameterthreshold<1-65535>:theerrorsymbolcol-
lectedinaperiod.Itis1bydefault.
Theparameterwindow<1-65535>:thesymbolnumberpe-
riod.Theunitismillion.Forexample,30representsthatcol-
lecting30,000,000symbolsisaperiod.Itis1bydefault.
8.Toconguretheerrorframe,usethefollowingcommand.
CommandFunction
zte(cfg)#setethernet-oamport
<portlist>link-monitorframe
threshold<1-65535>window<1-60>
Thisconguresthe
errorframe.
Theparameterthreshold<1-65535>:thenumberoferror
frame.Thedefaultvalueis1.
Theparameterwindow<1-60>:timeperiod.Thedefault
valueis1second.
9.Toconguretheperiodoferrorframe,usethefollowingcom-
mand.
CommandFunction
zte(cfg)#setethernet-oamport
<portlist>link-monitorframe-period
threshold<1-65535>window
<1-600000>
Thisconguresthe
periodoferrorframe.
Theframeperiodisdecidedbytheframenumberwhichisre-
ceivedduringaspeciedperiodbyswitch,thatis,aperiodis
tocollectaspeciednumberofframes.Whentheerrorframe
numberislargerthantheperiodreceivingthreshold,thelink
alarmwillbeappeared.
Theparameterthreshold<1-65535>:theerrorframenum-
ber ,thedefaultis1.
Theparameterwindow<1-600000>:theframenumber ,the
defaultvalueis100.theunitisthousand.1represents1000.
10.Tocongureerrorframesummary,usethefollowingcom-
mand.
188CondentialandProprietaryInformationofZTECORPORATION