EasyManua.ls Logo

Zte ZXR10 2900E Series - Figure 5-26 Sqinq Configuration Instance

Zte ZXR10 2900E Series
307 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter5ServiceConguration
ConguringSQinQ
TheSQinQcongurationincludesthefollowingcommands:
CommandFunction
zte(cfg)#setvlansqinqsession<1-400>customer-port
<port-id>customer-vlan<vlan-list>uplink-vlan<vlan-id>
EnablesSVLANfunction.
WhentheSQinQfunctionis
enabled,theuplinktrafcis
normallyforwardedinSPVLAN.
Thedownlinktrafcisnormally
forwardedinSPVLAN.Because
theUNIportbelongstoSPVLAN
inuntaggedmode,theSPVLAN
tagofdownlinkpacketswillbe
removed.
zte(cfg)#clearvlansqinqDeletesallSQinQsessions.
zte(cfg)#clearvlansqinqsession<1-400>DeletesthespeciedSQinQ
session.
showvlansqinq(allcongurationmodes)DisplaysallSQinQsessions.
showvlansqinqsession<1-400>(allcongurationmodes)DisplaysthespeciedSQinQ
session.
SQinQCongurationInstance
lCongurationDescription
Port1isacustomerport,andport2isanuplinkport.WhenCVLANis10and12,the
packetfromport1SPVLANis997and998respectively.SeeFigure5-26.
Figure5-26SQinQCongurationInstance
lCongurationProcedure
ConguretheSVLANinstance.
zte(cfg)#setvlan10,12addport1tag
zte(cfg)#setvlan997,998addport1untag
zte(cfg)#setvlan997,998addport2tag
zte(cfg)#setvlan10,12,997,998enable
zte(cfg)#setvlansqinqsession1customer-port1customer-vlan10uplink-vlan997
zte(cfg)#setvlansqinqsession2customer-port1customer-vlan12uplink-vlan998
lCongurationVerication
ThefollowingexampleshowshowtoshowtheSVLANinstance.