EasyManua.ls Logo

Zte ZXR10 2900E Series - Page 177

Zte ZXR10 2900E Series
307 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter5ServiceConguration
Period:10*100(ms)
LinkTimeOut:5(s)
Unidirection:nonsupport
PDUmaxsize:1518
Status:
Parser:forward
Multiplexer:forward
Stable:yes
/*yesrepresentsthatdiscoverysucceeds.norepresentsdiscoveryfails.*/
Discovery:done
/*discoverysucceeds.undonerepresentsthatdiscoveryfails*/
Loopback:off
PDURevision:92
RemoteDTE/*theremotedeviceinformation*/
-----------
Config:
Mode:active
LinkMonitor:support
Unidirection:nonsupport
RemoteLoopback:support
MibRetrieval:nonsupport
PDUmaxsize:1518
Status:
Parser:forward
Multiplexer:forward
Stable:yes
MacAddress:00.d0.d0.29.28.02
/*thesystemMACoftheremotedevice.
TheMACaddressis00.00.00.00.00.00whendiscoveryfails.*/
PDURevision:967
zte(cfg)#setethernet-oamremote-loopbackport2start
zte(cfg)#showethernet-oamport2discovery
PortId2:ethernetoamenabled
LocalDTE
-----------
Config:
Mode:active
Period:10*100(ms)
LinkTimeOut:5(s)
Unidirection:nonsupport
PDUmaxsize:1518
Status:
Parser:discard/*theparserstateisdiscard*/
Multiplexer:forward
5-129