ZXR102900ESeriesCongurationGuide
CommandFunction
zte(cfg)#cpu-threshold<30-90>SetstheCPUusagethreshold.
zte(cfg)#mem-threshold<60-90>Setsthememoryusagethreshold.
zte(cfg)#writeSavesthecurrentcongurationinformationtothe
Flashmemoryandrecoverstheinformationwhenthe
switchisrebooted.
zte(cfg)#clearuser<name>Deletesauser.
zte(cfg)#clearreboot-timeClearsautomaticrebootconguration.
zte(cfg)#terminalmonitor{on|off}Allowsorforbidsprintingthereal-timealarmlog
informationtotheterminal.
zte(cfg)#terminallog{on|off}Allowsorforbidswritinglogs.
zte(cfg)#terminallogtoFileSaveslogsintheRAMtotheFlashmemory.
zte(cfg)#terminallogtimer{enable|disable
|interval<1-720>}
Setsautomaticsavingofloginformation.
zte(cfg)#setbootpasswordto<string>Setsthepasswordforloggingintobootmode.
zte(cfg)#setbootpasswordclearDeletesthepasswordforloggingintobootmode.
zte(cfg)#setfanmode{auto|manual}Setsthefanoperatingmode.
zte(cfg)#setfanspeedSetsthefanoperatingspeed.
zte(cfg)#readconfig<filename>Readsthelocalleonthedeviceastheconguration.
zte(cfg)#settemperature-alarm<0-100>Setsthethresholdforover-temperaturealarmson
theswitch.
zte(cfg)#clearterminal-logClearsloginformation.
zte(cfg)#terminallogmodule
{all|arp-inspection|dhcp|radius|AAA}{
off|on}
Allows/forbidswritinglogsofamodule.
zte(cfg)#terminalmonitormodule{all|
arp-inspection|dhcp|radius|AAA}{off|on}
Allows/forbidsprintingreal-timealarmlogsofa
modulefortheterminal.
showreset-time(allcongurationmodes)Displaysautomaticlogouttimesettingoftheswitch
console.
showline-vty(allcongurationmodes)DisplaysTelnetuserlogintimeouttimesetting.
showloginauth(allcongurationmode)Displaysloginauthenticationmode.
showadminauth(allcongurationmodes)Displaysmanagementauthenticationstateand
authenticationmode.
showterminal(allcongurationmodes)Displaysterminallogcongurationinformation.
showterminallog(allcongurationmodes)DisplaystheterminalloginformationinRAM.
5-4