IES-1248-51/51A/53 User’s Guide
154 Chapter 18 xDSL Line Data
The following table describes the labels in this screen.
Table 30 xDSL Performance
LABEL DESCRIPTION
Line Rate Click Line Rate to display an ADSL port’s line operating values (see Section
18.1 on page 151).
Line Data Click Line Data to display an ADSL port’s line bit allocation (see Section 18.3 on
page 155).
Port Use this drop-down list box to select a port for which you wish to view
information.
Refresh Click Refresh to display updated information.
Port Name This section displays the name of the port.
Performance
Line Type “Fast” stands for non-interleaved (fast mode) and “Interleaved” stands for
interleaved mode.
Init This field displays the number of link-ups and link-downs.
ATUC/ATUR ES The Number of Errored Seconds transmitted (downstream) or received
(upstream) on this ADSL port.
ATUC/ATUR
SES
The Number of Severely Errored Seconds transmitted (downstream) or received
(upstream) on this ADSL port. Severely errored seconds contained 30% or more
errored blocks or at least one defect. This is a subset of the Down/Up Stream
ES.
ATUC/ATUR
UAS
The downstream or upstream number of UnAvailable Seconds.
Fast FEBE In fast mode, the number of Far End Block Errors (Far End Cyclic Redundancy
Checks).
Fast NEBE In fast mode, the number of Near End Block Errors (Near End Cyclic
Redundancy Checks).
Fast FEFEC In fast mode, the Far End number of ADSL frames repaired by Forward Error
Correction.
Fast NEFEC In fast mode, the Near End number of ADSL frames repaired by Forward Error
Correction.
Interleaved
FEBE
In interleaved mode, the number of Far End Block Errors (Far End Cyclic
Redundancy Checks).
Interleaved
NEBE
In interleaved mode, the number of Near End Block Errors (Near End Cyclic
Redundancy Checks).
Interleaved
FEFEC
In interleaved mode, the Far End number of ADSL frames repaired by Forward
Error Correction.
Interleaved
NEFEC
In interleaved mode, the Near End number of ADSL frames repaired by Forward
Error Correction.
LPR This is the number of times that the subscriber’s ADSL device has experienced a
Loss of Power (been off).
15 min, 1day history This section of the screen displays line performance statistics for the current and
previous 15-minute periods, as well as for the current and previous 24 hours.
lofs The number of Loss Of Frame Seconds that have occurred within the period.
loss The number of Loss Of Signal Seconds that have occurred within the period.
lols The number of Loss Of Link Seconds that have occurred within the period.