IES-1248-51/51A/53 User’s Guide
Chapter 4 MDF Connections 61
CHAPTER 4
MDF Connections
This chapter shows you how to connect the Telco-50 connectors to an MDF.
4.1 MDF Connections Overview
Observe the following before you start:
See Appendix B on page 445 for the gauge of telephone wire to use.
Follow the pin assignments shown in Appendix C on page 449 to wire Telco-50 cables to
Telco-50 connectors.
See Chapter 1 on page 41 and Appendix C on page 449 for details on how to make the
management connections.
4.2 MDF (Main Distribution Frame)
An MDF is usually installed between subscribers’ equipment and the telephone company
(CO) in a basement or telephone room. The MDF is the point of termination for the outside
telephone company lines coming into a building and the telephone wiring in the building.
Figure 15 MDF (Main Distribution Frame) Wiring
Connect wiring to end-user equipment to the lower ports of an MDF and connect wiring
from the telephone company to the upper ports of an MDF (see the previous figure).
Some MDFs have surge protection circuitry built in between the two banks; thus, do not
connect telephone wires from the telephone company directly to your IES-1248.