Chapter 46 Alarm Commands 301
46.7 Log Format
The following table describes the columns in the list.
46.8 Alarm History Show Command
Syntax:
ras> alarm history show [<severity>|all] [<alarm>|all] [<condition>|all]
[<sdate>|all] [<edate>|all] [for|rev] [detail]]
where
This command displays historic alarms by severity, alarm category, alarm condition and/or
dates.
Table 96 Log Format
LABEL DESCRIPTION
no This is the index number of the alarm entry in this list display.
alarm This is the category of alarms. eqpt represents equipment alarms. dsl represents
Digital Subscriber Line (DSL) alarms. enet represents Ethernet alarms. sys
represents system alarms.
condition There is a condition code number for the specific alarm message and a text
description for the condition under which the alarm applies.
facility This is the log facility (local1~local7) on the syslog server where the system is to
log this alarm. This is for alarms that send alarms to a syslog server.
snmp This displays “V” if the system is to send this alarm to an SNMP server. It
displays “-“ if the system does not send this alarm to an SNMP server.
syslog This displays “V” if the system is to send this alarm to a syslog server. It displays
“-“ if the system does not send this alarm to a syslog server.
severity This is the alarm severity level (critical, major, minor or info).
clearable This displays “V” if the alarm clear command removes the alarm from the
system. It displays “-“if the alarm clear command does not remove the alarm
from the system.
<sdate> =
The start date, in yyyy/mm/dd format.
<edate> =
The end date, in yyyy/mm/dd format.
[for|rev] =
The displaying order. Use for to display in chronological order
starting from the oldest alarm. Use
rev to display in reverse
chronological order starting from the most recent alarm.
[detail] =
Display in-depth alarm information.