IES-1248-51/51A/53 User’s Guide
Chapter 46 Alarm Commands 299
The following example displays the port alarm thresholds for all ports. “ifindex” identifies the
interface.
46.5 Alarm Port Set Command
Syntax:
ras> alarm port set <all|enet1|enet2|port> <severity>
where
This command sets the alarm severity threshold for recording alarms on an individual port(s).
The system reports an alarm on a port if the alarm has a severity equal to or higher than the
port’s threshold.
Figure 150 Alarm Port Show Command Example
ras> alarm port show
Press any key to continue, 'e' to exit, 'n' for nopause
no ifindex severity
----- ---------- -----------
01 01 minor
02 02 minor
03 03 minor
04 04 minor
05 05 minor
06 06 minor
07 07 minor
08 08 minor
09 09 minor
10 10 minor
11 11 minor
12 12 minor
13 13 minor
14 14 minor
15 15 minor
16 16 minor
17 17 minor
18 18 minor
19 19 minor
20 20 minor
Press any key to continue, 'e' to exit, 'n' for nopause
<all|enet1|enet
2|port>
=
Ports on the IES-1248.