IES-1248-51/51A/53 User’s Guide
302 Chapter 46 Alarm Commands
The following example displays the historic critical level alarms for all alarm categories, and
all conditions.
46.9 Alarm History Clear Command
Syntax:
ras> alarm history clear [<alarm>|all <condition>|all] <severity>
This command removes historic alarm entries by alarm category, alarm condition or severity.
The following example removes the historic minor level alarms for all alarm categories, and
all conditions.
46.10 Alarm XEdit Command
Syntax:
ras> alarm xedit <alarm>|all <cond>|<condcode> <severity> <fac>
<target>[,<target>] [clearable]
where
Figure 153 Alarm History Show Command Example
ras> alarm history show critical all all all all rev detail
no alarm condition severity timestamp source
------ ------ ------------------------ -------- -------------- -------
1 eqpt +fan_err critical 07/28 15:23:35 eqpt
* IES-1248:Fan 2 speed 0, low 2000, high 8000
2 eqpt +fan_err critical 07/28 15:23:35 eqpt
* IES-1248:Fan 3 speed 0, low 2000, high 8000
3 eqpt +fan_err critical 07/28 15:23:33 eqpt
* IES-1248:Fan 1 speed 0, low 2000, high 8000
Figure 154 Alarm History Clear Command Example
ras> alarm history clear minor
<cond> =
all|condition This is the text description for the condition
under which the alarm applies. Use the
alarm tablelist to
find alarm conditions.
<condcode > =
The condition code is the number of a specific alarm message.
Use the
alarm tablelist to find alarm condition codes.