26 ©2013 2GIG Technologies Inc. All Rights Reserved.
Go!Control Wireless Security System | Install Guide
modethesystemisin.Typicalusewouldbeforwireless
carbonmonoxidedetectors.Thissensortypeisalways
activeandcannotbebypassed.
(16) 24-hour Fire with Verification †
Thissensortypeiscontinuouslyarmed24‐hoursaday.A
sensorprogrammedtothistypecantriggerthelocal
alarmfiresounderandthebelloutputregardlessofthe
modethesystemisin.Typicalusewouldbeforwireless
smokedetectors.Thissensortypeisalwaysactiveand
cannotbebypassed.
Fo
rverification,thissensortypemustbeviolatedtwicein
twominutes,orremainviolatedfor30seconds.Ifany
otherfiresensor(verifiedsensortypeornot)violates
withintwominutes,bothsensorswillcauseafirealarm.
(23) No Response Type
Thissensortypeisaspecialzonethatcanbemonitored
foractivityorinactivitybytheCentralStation.Itdoesnot
affectsecuritysystemstatus.
(24) Silent Burglary
Thissensortypeisforsilenttriggeringtheburglaryalarm
withperimeterdoorsandwindowsthatwillnotbeused
toenterorexittheprotectedpremiseswhilethesystem
isarmed.TheControlPanel’ ssounderandthebelloutput
willnotactivate.
Aninstantsilentalarmwilloccurwhenthistypeof
senso
ristriggeredwiththesystemarmedineitherthe
StayModeorAwayMode.
†IndicatesSensortypesthatarenotallowedfor
hardwiredloops.