Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN
Description des sous-ensembles 01/2011 Page 183
4.7.3 Hardware and software configuration
The following configurations are performed by MMC from Aastra Management Portal:
• configuration of the T lines, S or DECT terminal.
• Master/Slave mode of the synchronisation port (by default set to Master).
• Priority/Non Priority mode of the synchronisation port (by default set to Priority).
• setting of the input level for the external music on hold.
• setting of the delay to be applied to the DECT synchronisation signal.
The built-in 3 V battery is still in circuit (no microswitch).
4.7.4 Installation and wiring
The following equipment connected to the UCV-S card has the installation details
described in Section 5.6:
• Operating console
• External music source
• Common bell
• Alarm bell.